Troubleshoot your problem

What type of problem are you having?
Air Conditioning
Please select one

This may be caused by your thermostat settings:

Solution

  • Be sure your thermostat is turned ON
  • Be sure the thermostat is set to ā€œCool Modeā€ and the Fan is set to ā€œAutoā€.
  • Be sure the thermostat set point is ā€œat leastā€ set to 3 degrees LOWER than the displayed room temperature.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Your air filter(s) may be dirty

Solution

Check ALL A/C filters for cleanliness. Clean and/or replace (depending on filter type) if visibly dirty. ** All supply vents and return grills should be open and unrestricted for proper system air flow and cooling effect**

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Is the indoor fan running and air blowing out of your vents?

**Your unit may be equipped with a safety float switch that is connected to the condensate drain at your indoor unit. The safety switch could be wired to shut down the outside unit ONLY to prevent further condensate backup and flooding.**

Solution

  • Check for a clogged condensate drain and clear if it appears clogged or there is evidence of water on the floor at the indoor unit or standing water is present inside the condensate pipe. NEVER use any chemicals including but not limited to bleach, vinegar, Drain-O inside your condensate drain. The use of anything OTHER THAN HOT water will cause eventual coil rupture and refrigerant leaks.
  • The use of a Wet Vac is preferable for homeowner fixes of a clogged drain.
  • Give your air conditioner a couple of minutes and see if it cycles on.

***NOTE--- Your unit most likely has a built in time delay. You MUST allow 10 minutes for the time delay to reset and the system to start-up*** DO NOT keep adjusting the thermostat during this time.

Did that solve your problem?

Sounds like you need expert care.

Please turn off your system and schedule an appointment.

Schedule for Maintenance

Routine Maintenance of your air conditioner is indicated by the presence of a clogged drain.

Schedule for Maintenance

There may be a problem with the electrical service or system components. Your ACā€™s circuit breaker may have tripped:

Solution

  • Find your breaker box and look for the circuit(s) labeled AC/Furnace/Air Handler
  • Try flipping those circuits to ā€œoffā€ and then ā€œonā€ for all accessible fuses and breakers labeled for the AC/Furnace/Air Handler
  • Give your air conditioner a couple of minutes and see if it cycles on

***NOTE--- Your unit most likely has a built in time delay. You MUST allow 10 minutes for the time delay to reset and the system to start-up*** DO NOT keep adjusting the thermostat during this time.

Did that solve your problem?

Sounds like you need expert care.

Please turn off your system and get professional help.Breakers and fuses do NOT flip and blow without cause. A service call is indicated to evaluate further.

Schedule for Maintenance

Sounds like you need expert care.

Please turn off your system and schedule an appointment.

Schedule for Maintenance

There may be a problem with the electrical service or system components. Your ACā€™s circuit breaker may have tripped:

Solution

  • Find your breaker box and look for the circuit(s) labeled AC/Furnace/Air Handler
  • Try flipping those circuits to ā€œoffā€ and then ā€œonā€ for all accessible fuses and breakers labeled for the AC/Furnace/Air Handler
  • Give your air conditioner a couple of minutes and see if it cycles on

***NOTE--- Your unit most likely has a built in time delay. You MUST allow 10 minutes for the time delay to reset and the system to start-up*** DO NOT keep adjusting the thermostat during this time.

Did that solve your problem?

Sounds like you need expert care.

Please turn off your system and get professional help. Breakers and fuses do NOT flip and blow without cause. A service call is indicated to evaluate further.

Schedule for Maintenance

Sounds like you need expert care.

Please turn off your system and schedule an appointment.

Schedule for Maintenance

Solution

  • Be sure your thermostat is turned ON
  • If your thermostat uses batteries, check and replace with new batteries as indicated.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

**Your unit may be equipped with a safety float switch that is connected to the condensate drain at your indoor unit. The safety switch could be wired to shutdown the system and your thermostat to prevent further condensate backup and flooding. Often the safety switches are wired to cause a BLANK thermostat to alert the homeowner of a potential drain issue**

Solution

  • Check for a clogged condensate drain and clear if it appears clogged or there is evidence of water on the floor at the indoor unit or standing water is present inside the condensate pipe. NEVER use any chemicals including but not limited to bleach, vinegar, Drain-O inside your condensate drain. The use of anything OTHER THAN hot water will cause eventual coil rupture and refrigerant leaks.
  • The use of a Wet Vac is preferable for homeowner fixes of a clogged drain.
  • Give your air conditioner a couple of minutes and see if it cycles on.

***NOTE--- Your unit most likely has a built in time delay. You MUST allow 10 minutes for the time delay to reset and the system to start-up*** DO NOT keep adjusting the thermostat during this time.

Did that solve your problem?

Sounds like you need expert care.

Routine Maintenance of your air conditioner is indicated by the presence of a clogged drain.

Schedule for Maintenance

Sounds like you need expert care.

Please turn off your system and get professional help.

Schedule for Maintenance

This may be caused by your thermostat settings:

Fans set in the fan setting of ā€œONā€ will introduce moist, humid outdoor air into the home. Changing the Fan setting to ā€œAutoā€ often will eliminate this problem.

Solution

  • Check your thermostat settings.
  • Be sure the Fan Setting is NOT in the ON position.
  • Set the Fan Setting to the AUTO position.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

Please turn off your system and get professional help.

Schedule for Maintenance

Often reptiles, rodents and the like will make their way into your system. When that occurs, you might notice an associated noise from contact with motorā€™s fan blades.

Solution

  • Turn your system OFF
  • Check your outdoor unit for the presence of snakes, lizards, rodents.
  • If present, safely remove prior to further operation.
  • Do not attempt to open the outside unitā€™s cabinet yourself.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

Please turn off your system and get professional help.

Schedule for Maintenance
Heating
What type of heat do you have?
What type of heating problem are you having?

This can be caused by your thermostat

Solution

  • If your home uses a Summer/Winter switch, be sure the switch is switched to the Winter position.
  • Be sure your thermostat is turned ON.
  • Be sure the thermostat is set to the HEAT setting.
  • Set the thermostat set point to at least 3 degrees ABOVE the thermostatā€™s displayed room temperature.
  • Be sure the FAN setting is in the AUTO position.

***NOTE--- Your unit most likely has a built-in time delay. You MUST allow 10 minutes for the time delay to reset and the system to start-up*** DO NOT keep adjusting the thermostat during this time.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

This can be caused by lack of proper gas flow or unlit pilot light.

Solution

  • Be sure the gas valve to your gas furnace is fully open.
  • If your gas furnace uses a pilot light, be sure the pilot light is lit.
  • Follow the manufacturerā€™s recommendations for lighting the pilot light.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Your air filter(s) may be dirty.

Solution

  • Check ALL A/C- furnace filters for cleanliness. Clean and/or replace (depending on filter type) if visibly dirty.

** All supply vents and return grills should be open and unrestricted for proper system air flow and cooling effect**

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Is the indoor fan running and air blowing out of your vents?

Sounds like you need expert care.

Please turn off your system and schedule an repair appointment.

Schedule for Maintenance

There may be a problem with the electrical service or system components. Your furnaceā€™s circuit breaker may have tripped:

Solution

  • Find your breaker box and look for the circuit(s) labeled AC/Furnace/Air Handler
  • Try flipping those circuits to ā€œoffā€ and then ā€œonā€ for all accessible fuses and breakers labeled for the AC/Furnace/Air Handler
  • Give your air conditioner a couple of minutes and see if it cycles on

***NOTE--- Your unit most likely has a built-in time delay. You MUST allow 10 minutes for the time delay to reset and the system to start-up*** DO NOT keep adjusting the thermostat during this time.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

Please turn off your system and schedule an repair appointment.

Schedule for Maintenance

Solution

  • Be sure your thermostat is turned ON
  • If your thermostat uses batteries, check and replace with new batteries as indicated.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

Please turn off your system and schedule an repair appointment.

Schedule for Maintenance

Smells from your gas furnace should ALWAYS be evaluated by a licensed professional. Whether the smell you are experiencing is that of an electrical or metallic nature or the rotten egg smell that is injected into the gas lines (by the gas company) to alert technicians and homeowners of a potential gas leak. None of these should be taken lightly or ignored.

Solution

  • Turn the gas furnace OFF.
  • Close the gas valve to the gas line.
  • Leave your home and call the gas company for service.
  • DO NOT OPERATE SYSTEM UNTIL CLEARED BY A LICENSED PROFESSIONAL

Schedule an appointment for repair IMMEDIATELY.

Schedule for Maintenance
What type of problem are you having?

This can be caused by your thermostat:

Solution

  • Be sure your thermostat is turned ON.
  • Be sure the thermostat is set to the HEAT setting.
  • Set the thermostat set point to at least 3 degrees ABOVE the thermostatā€™s displayed room temperature.
  • Be sure the FAN setting is in the AUTO position.

***NOTE--- Your unit most likely has a built-in time delay. You MUST allow 10 minutes for the time delay to reset and the system to start-up*** DO NOT keep adjusting the thermostat during this time.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Your air filter(s) may be dirty.

Solution

  • Check ALL A/C- furnace filters for cleanliness. Clean and/or replace (depending on filter type) if visibly dirty.

** All supply vents and return grills should be open and unrestricted for proper system air flow and cooling effect**

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Is the indoor fan running and air blowing out of your vents?

Sounds like you need expert care.

Please schedule a repair appointment

Schedule for Maintenance

There may be a problem with the electrical service or system components. Your furnaceā€™s circuit breaker may have tripped:

Solution

  • Find your breaker box and look for the circuit(s) labeled AC/Furnace/Air Handler
  • Try flipping those circuits to ā€œoffā€ and then ā€œonā€ for all accessible fuses and breakers labeled for the AC/Furnace/Air Handler
  • Give your air conditioner a couple of minutes and see if it comes on

***NOTE--- Your unit most likely has a built-in time delay. You MUST allow 10 minutes for the time delay to reset and the system to start-up*** DO NOT keep adjusting the thermostat during this time.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

** Should your heat pump system have Supplemental Emergency heat installed, you can change your thermostat setting from Heat to AUX/Emergency Heat for temporary heating until service is available.**

Please schedule a repair appointment

Schedule for Maintenance

Solution

  • Be sure your thermostat is turned ON
  • If your thermostat uses batteries, check and replace with new batteries as indicated.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

Please schedule a repair appointment

Schedule for Maintenance

If you are just turning your heat on for the first time this winter, it is not unusual, and in fact, is quite common for you to experience a dusty, burning smell. Most chances are that your furnace is actually burning away that old dust, debris and buildup that is present on your heat pumpā€™s emergency backup electric heat strips. This is very normal. However, should the smell continue or you feel alarmed, scheduling a repair call would be the prudent approach.

Solution

  • Allow the dusty burning smell to dissipate. It should clear within an hour or so, depending upon amount of buildup present.
  • Be sure the A/C- furnace filter is clean and/or replaced as indicated.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

Please schedule a repair appointment

Schedule for Maintenance

This is due to your system operating in the ā€œDefrost Modeā€: This happens during the heating season and is actually normal operation of the system. Outdoor condensing coils will tend to have a buildup of ice occur during low outside (ambient) temperatures. This occurs especially during moist conditions. This buildup will cause a unit to loose efficiency by blocking air flow. The system will regularly place itself in ā€œdefrost modeā€ to clear its coil and improve efficiency and airflow.

Solution

  • Continue normal operation.
  • Do not be alarmed should you experience a short burst of cooler air flowing from the air vents. It is actually the air conditioner functioning in the cool setting. The system will activate the supplemental heat to offset this cooling effect during the defrost cycle. The heating cycle will return to normal heating operation when the defrost cycle terminates.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

Please schedule a repair appointment

Schedule for Maintenance
What type of problem are you having?

This can be caused by your thermostat:

Solution

  • Be sure your thermostat is turned ON.
  • Be sure the thermostat is set to the HEAT setting.
  • Set the thermostat set point to at least 3 degrees ABOVE the thermostatā€™s displayed room temperature.
  • Be sure the FAN setting is in the AUTO position.

***NOTE--- Your unit most likely has a built-in time delay. You MUST allow 10 minutes for the time delay to reset and the system to start-up***DO NOT keep adjusting the thermostat during this time.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Your air filter(s) may be dirty.

Solution

  • Check ALL A/C- furnace filters for cleanliness. Clean and/or replace (depending on filter type) if visibly dirty.

** All supply vents and return grills should be open and unrestricted for proper system air flow and cooling effect**

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Your air filter(s) may be dirty.

Solution

  • Check ALL A/C- furnace filters for cleanliness. Clean and/or replace (depending on filter type) if visibly dirty.

** All supply vents and return grills should be open and unrestricted for proper system air flow and cooling effect**

Did that solve your problem?

Sounds like you need expert care.

Please schedule a repair appointment

Schedule for Maintenance

There may be a problem with the electrical service or system components. Your furnaceā€™s circuit breaker may have tripped:

Solution

  • Find your breaker box and look for the circuit(s) labeled AC/Furnace/Air Handler
  • Try flipping those circuits to ā€œoffā€ and then ā€œonā€ for all accessible fuses and breakers labeled for the AC/Furnace/Air Handle
  • Give your air conditioner a couple of minutes and see if it cycles on

***NOTE--- Your unit most likely has a built-in time delay. You MUST allow 10 minutes for the time delay to reset and the system to start-up*** DO NOT keep adjusting the thermostat during this time.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

Please turn off your system and schedule an repair appointment.

Schedule for Maintenance

Solution

  • Be sure your thermostat is turned ON
  • If your thermostat uses batteries, check and replace with new batteries as indicated.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

Schedule for Maintenance

If you are just turning your heat on for the first time this winter, it is not unusual, and in fact, is quite common for you to experience a dusty, burning smell. Most chances are that your furnace is actually burning away that old dust, debris and buildup that is present on your heat pumpā€™s emergency backup electric heat strips. This is very normal. However, should the smell continue or you feel alarmed, scheduling a repair call would be the prudent approach.

Solution

  • Allow the dusty burning smell to dissipate. It should clear within an hour or so, depending upon amount of buildup present.
  • Be sure the A/C- furnace filter is clean and/or replaced as indicated.

Did that solve your problem?

Awesome!!

Glad we were able to help you solve your problem. Weā€™ll be here. If you should need us again. Donā€™t forget to BOOKMARK our site for any future needs.

Sounds like you need expert care.

Schedule for Maintenance

Our Featured Services

Air Conditioning

Air Conditioning

Air Conditioning

Our residential AC installation provides massive relief for our Florida customers. They know that we offer them the best service. Letā€™s look at why our service qualifies as the best.

Heat Pump Installation & Replacement

Heating

Heating

Cold winter days happen, even in Florida. Fortunately, a reliable heat pump can offer an excellent buffer against those chilly days.

Air Conditioning

Indoor Air Quality

Indoor Air Quality

Indoor air quality is vitally important to a familyā€™s health. Pollutants such as dust, pet dander, smoke and pollen can get trapped inside todayā€™s well-insulated, tightly sealed homes.

Air Conditioning

Ductless

Ductless

Ductless systems are a fascination to the homeowners. They are meant to heat or cool a particular point in a home.

Air Conditioning

Thermostat

Thermostat

There are so many choices when it comes to selecting a thermostat.

Air Conditioning

Commercial

Commercial

Our Commercial clients are just as valued as our residential clients. We offer: installation, repair and maintenance. Our clients can expect the same great services.

Why Choose Us

Central Air & Heat, Inc., is a small company specializing in installation, service and repairs for all your air conditioning needs. We are located in Groveland, FL and proudly serving the surrounding area. With over seven years of extensive experience in the industry, you can rest assured you are in good hands. Our mission is to provide our customers with the best products and the highest quality of service. We will give you our honest opinion about every job, and offer you various cost-saving options and suggestions. We value our customers and are committed to keeping them satisfied. So, why not give us a call today? Let our work speak for itself.

  • Extended Labor Warranty Available
  • Weā€™ll Always Try to Fix it First!!
  • Maintenance Agreement Available
  • 100% Satisfaction Guarantee
  • We do it right or do it over!
  • See what a few of our current customers have to say by clicking the yellow stars at the top of the page